Engineering & Project Management · 03

Earthquake-Resistant Design and Seismic Isolation

For seismically isolated buildings we carry out structural design, specialist design coordination, procurement and installation together.

Seismic isolators at the Star of Bosphorus Data Center in Tepeören, TuzlaStar of Bosphorus · Seismic isolators

What we do

Istanbul lies in a major earthquake zone with a seismic history going back thousands of years. In critical buildings we treat keeping operations running during an earthquake, and protecting the equipment investment, as the core objectives of the design.

At the Star of Bosphorus Data Center, the structural seismic isolation system (designed to FEMA standards, taking into account the correlation of seismic events over the last 2,500 years, and sized for the DD-1 ground motion level) is a first of its kind in Türkiye.

Scope

What we undertake in earthquake-resistant design:

  • Structural design of seismically isolated buildings
  • Specialist design coordination
  • Procurement and installation of seismic isolation systems
  • Performance-based structural system design
  • Compliance with the Turkish Building Earthquake Code
Structural design section of the Star of Bosphorus Data CenterStar of Bosphorus · Structural design section

Our approach

4 principles
  1. 01

    Operational continuity

    Seismic isolation protects the whole building against earthquakes and prevents the interruptions an earthquake could cause; we build the design around this objective.

  2. 02

    International standards

    We base seismic isolation design on the internationally recognised FEMA standards and use the region’s seismic history as a design input.

  3. 03

    A performance target

    We design the structural system for the target performance at a defined earthquake level; at Çelik İba Hadımköy the design targets Immediate Occupancy performance at the DD-1 earthquake level.

  4. 04

    One team from design to installation

    By carrying out structural design, specialist design coordination, procurement and installation together, we make sure design decisions reach the site in full.

References

Aerial photo of the Star of Bosphorus Data Center in Tepeören, Tuzla, at sunsetFacility · Sunset
Featured reference

Star of Bosphorus Data Center

Tepeören, Tuzla · Data centre · A first in Türkiye

Seismically isolated building · FEMA standards

Ground motion level
DD-1
Seismic history considered
2,500years
Enclosed area
45,000m²

Sign of the City Awards 2019: Best Industrial / Logistics Building (Under Construction)

Other references

Get in touch about earthquake-resistant design.

Talk to our engineering team; we are with you from structural design through procurement and installation.

+90 216 304 00 00 · Erenköy, Kadıköy